100W Quad Output with PFC Function
- Universal AC input/Full range
- PF>0.98@115V AC;>0.95@230V AC
- Protections: Short circuit /Over load/ Over voltage
- Cooling by free air convection
- Approvals: UL/CUL/TUL/CB/CE
- 100%full load burn-in test
AC input voltage range…..90~264V AC, 127~370V DC
AC inrush current………….Cold start, 40A at 230V AC
DC adjustment range……..CH1:-5~+10% (PPQ-1003:CH1&2 -5~+10%)
Over load protection..…105%~135%hiccup mode, auto-recovery (PPQ-100)
105%~135% constant current, auto-recovery(PPQ-1003)
Over voltage protection……3.6V~4.3V for 3.3V; 5.75~6.75 for 5.0V
Leakage current…………….Less than 3.5mA at 240V AC (PPQ-1003:<1Ma)
Setup, rise, hold up time……800ms, 50ms, 16ms at full load and 230V AC
Withstand voltage………….I/P-O/P:3KV AC, I/P-FG: 1.5KV AC,1minute
Working temperature……..-10~60℃ (refer to output derating curve)
Safety standards…………UL1950, TUV EN60950 approved
EMS standards…………...EN55022 class B, EN61000-3-2,3
…… EN61000-4-2,3,4,5,6,8,11, EN50204
Connection…….…5P+5P+8P/3.96mm pitch, P/N:JST B5/5/8P-VH(PPQ-100)
……3P+5P+8P/3.96mm pitch, P/N:JST B3/5/8P-VH(PPQ-1003)
Packing…………………0.62kg;24pcs/15.5kg/1.34CUFT
Model No |
Output |
Tolerance |
Ripple&Noise |
Efficiency |
Maximal |
SP100B-3A |
3.3V,0~15A |
±3% |
80MV |
75% |
119W |
5V,2~15A |
±3% |
80MV |
12V,0.2~3A |
±6% |
120MV |
-5V,0~1A |
±6% |
100MV |
SP100B-3B
|
3.3V,0~15A |
±3% |
80MV |
75% |
121W |
5V,2~15A |
±3% |
80MV |
12V,0.2~3A |
±6% |
120MV |
-12V,0~1A |
±6% |
120MV |
SP100B-3C |
3.3V,0~15A |
±3% |
80MV |
75% |
120W |
5V,2~15A |
±3% |
80MV |
15V,0.2~3A |
+10%,-5% |
150MV |
-15V,0~1A |
±6% |
150MV |
SP100B-3D |
3.3V,0~15A |
±3% |
80MV |
75% |
124W |
5V,2~15A |
±3% |
80MV |
12V,0.2~3A |
±6% |
120MV |
24V,0~1 |
±6% |
240MV |
|