240W Single Output Power Supply
- AC input range auto sensing
- Built-in passive PFC choke
- Protections: Short circuit/Over load/Over voltage/Over temp.
- Fixed switching frequency at 75KHZ
- Forced air cooling by built-in DC fan
- Approvals: UL/CUL/TUV/CB/CE
- Cooling fan ON/OFF auto control
- 100% full load burn-in test
AC input voltage range…...88~132V AC/176~264V AC auto-sensing
AC inrush current………….Cold start, 18A at 115V AC, 36A at 230V AC
DC adjustment range……..±10% rated output voltage
Over load protection……….105%~135% hiccup mode, auto-recovery
Over voltage protection……115%~150% rated output voltage
Setup, rise, hold up time ……..1000ms, 20ms, 20ms at full load and 230V AC
Withstand voltage…………..I/P-O/P:3KV AC, I/P-FG: 1.5KV AC,1minute
Working temperature………0~50℃@100%,-10℃@80%,60℃@60%load
Safety standards……………UL1950, TUV EN60950 approved
(7.5V design reger to UL1950)
EMC standards...................EN55022 class B, EN61000-3-2,-3
….EN61000-4-2,3,4,5,6,8,11, EN50204
Connection………………….7P/9.5mm pitch terminal block
Packing………………… …..1.2kg:12pcs/15.3kg/0.9CUFT
Model No |
Output |
Tolerance |
Ripple&Noise |
Efficiency |
SP240A-5 |
5V,0~40A |
±5% |
80MV |
78% |
SP240A-7.5 |
7.5V,0~30A |
±5% |
80MV |
80% |
SP240A-12 |
12V,0~18A |
±3% |
120MV |
85% |
SP240A-15 |
15V,0~15A |
±3% |
150mv |
83% |
SP240A-24 |
24v,0~10A |
±3% |
240MV |
84% |
SP240A-30 |
30V,0~8.0A |
±3% |
300MV |
85% |
SP240A-48 |
48V,0~5.0A |
±3% |
480MV |
87% |
|